NEC Storage M100

 Á¦Ç° Á¤º¸ (NEC Storage M100)
 NEC Storage M100 3.5" µå¶óÀÌºê ¸ðµ¨ Á¦Ç° »ç¾ç
¸ðµ¨¸íM100 3.5" µå¶óÀÌºê ¸ðµ¨
Chassis Structure Up to 7(seven) 3.5" and 2.5" Disk Enclosures can be connected to the Disk Array Controller under the condition that the number of HDD slots should be up to 96.
HDD slots in a chassis;
  Disk Array Controller(3.5"):12
  Disk Enclosure(3.5"):12
  Disk Enclosure(2.5"):24
Host Interface FC(8Gbps), iSCSI(1Gbps or 10Gbps), SAS(6Gbps)
Number of Host Port Dual controller model: FC:4 or 8, SAS:8, iSCSI:4,FCx4+iSCSI(1G)x4
Single controller model: FC:2 or 4, SAS:4, iSCSI:2,FCx2+iSCSI(1G)x2
Cache Memory Capacity Dual controller model: 8GB
Single controller model: 4GB
Backup method Save to flash memory
RAID level RAID-0, 1, 5, 6, 10, 50, 60, TM
Drives Interface SAS(6Gbps)
Type / Capacity / Rotation Speed SAS HDD 3.5" 300GB,450GB,600GB(15,000rpm)
Nearline SAS HDD 3.5" 1TB,2TB,3TB,4TB(7,200rpm)
SAS SSD 3.5" 100GB,200GB,400GB,800GB
Encryption SAS HDD/NL SAS HDD 3.5" 600GB(15,000rpm)/4TB(7,200rpm)
Max. Storage Capacity (*1) SAS HDD 44.5TB
Nearline SAS HDD 303.3TB
SAS SSD 6.6TB
Encryption SAS HDD/NL SAS HDD 44.5TB/303.3TB
Number of Drives (*2) 3 - 96
Support OS (*3) Windows, Linux, VMware
Chassis Dimensions (width x depth x height) Disk Array Controller 482.0 x 513.2 x 87.8 mm (2U, w/o Front Bezel)
482.0 x 545.2 x 87.8 mm (2U, w/ Front Bezel)
Disk Enclosure 482.0 x 513.2 x 87.8 mm (2U, w/o Front Bezel)
482.0 x 545.2 x 87.8 mm (2U, w/ Front Bezel)
Weight Disk Array Controller 31kg or less
Disk Enclosure 29kg or less
Power Requirements AC100 - 240V single phase 50/60Hz
Power Consumption(Max./ @25 deg.C) Disk Array Controller (*4) SAS HDD 485W / 400W
Nearline SAS HDD 435W / 350W
Disk Enclosure SAS HDD 315W / 265W
Nearline SAS HDD 265W / 215W
Temperature Operating: 5 to 40 degrees Celsius (41 to 104 degrees Fahrenheit)
Non-operating: -10 to 60 degrees Celsius (14 to 140 degrees Fahrenheit)
Relative Humidity Operating: 10 to 80%RH
Non-operating: 5 to 80%RH

*1: Calculated on "1GB=1,024^3B","1TB=1,024^4B" basis.

*2: Up to 12 SSD can be installed.

*3: There might be some restrictions on the OS when connected with disk arrays.
     For more information, please feel free to contact NEC.

*4: Host interface is iSCSI(10Gbps).

 NEC Storage M100 2.5" µå¶óÀÌºê ¸ðµ¨ Á¦Ç° »ç¾ç
¸ðµ¨¸íM100 2.5" µå¶óÀÌºê ¸ðµ¨
Chassis Structure Up to 7(seven) 3.5" and 2.5" Disk Enclosures can be connected to the Disk Array Controller under the condition that the number of HDD slots should be up to 96.
HDD slots in a chassis;
  Disk Array Controller(2.5"):24
  Disk Enclosure(2.5"):24
  Disk Enclosure(3.5"):12
Host Interface FC(8Gbps), iSCSI(1Gbps or 10Gbps), SAS(6Gbps)
Number of Host Port Dual controller model: FC:4 or 8, SAS:8, iSCSI:4,FCx4+iSCSI(1G)x4
Single controller model: FC: 2 or 4, SAS:4, iSCSI:2,FCx2+iSCSI(1G)x2
Cache Memory Capacity Dual controller model: 8GB
Single controller model: 4GB
Backup method Save to flash memory
RAID level RAID-0, 1, 5, 6, 10, 50, 60, TM
Drives Interface SAS(6Gbps)
Type / Capacity / Rotation Speed SAS HDD 2.5" 300GB,450GB,600GB,900GB,1.2TB(10,000rpm)
Nearline SAS HDD 2.5" 1TB(7,200rpm)
SAS SSD 2.5" 100GB,200GB,400GB,800GB
Encryption SAS HDD 2.5" 600GB(10,000rpm)
Max. Storage Capacity (*1) SAS HDD 90.6TB
Nearline SAS HDD 76.1TB
SAS SSD 6.6TB
Encryption SAS HDD 44.5TB
Number of Drives (*2) 3 - 96
Support OS (*3) Windows, Linux, VMware
Chassis Dimensions (width x depth x height) Disk Array Controller 482.0 x 513.2 x 87.8 mm (2U, w/o Front Bezel)
482.0 x 545.2 x 87.8 mm (2U, w/ Front Bezel)
Disk Enclosure 482.0 x 513.2 x 87.8 mm (2U, w/o Front Bezel)
482.0 x 545.2 x 87.8 mm (2U, w/ Front Bezel)
Weight Disk Array Controller 31kg or less
Disk Enclosure 29kg or less
Power Requirements AC100 - 240V single phase 50/60Hz
Power Consumption(Max./ @25 deg.C) Disk Array Controller (*4) SAS HDD 485W / 395W
Nearline SAS HDD 450W / 365W
Disk Enclosure SAS HDD 310W / 260W
Nearline SAS HDD 275W / 225W
Temperature Operating: 5 to 40 degrees Celsius (41 to 104 degrees Fahrenheit)
Non-operating: -10 to 60 degrees Celsius (14 to 140 degrees Fahrenheit)
Relative Humidity Operating: 10 to 80%RH
Non-operating: 5 to 80%RH

*1: Calculated on "1GB=1,024^3B","1TB=1,024^4B" basis.

*2: Up to 12 SSD can be installed.

*3: There might be some restrictions on the OS when connected with disk arrays.
     For more information, please feel free to contact NEC.

*4: Host interface is iSCSI(10Gbps).